Define Control Plan Template Lines
Explanation
Each control plan template consists of two levels: a header and one or more lines. This activity is used to create 
new control plan template lines.
For each control plan template line, the sample size has to be calculated when 
an analysis is created. To calculate the sample size, an inspection code has to 
be defined.
The inspection type specifies whether the sample size is based on a fixed 
quantity or a sample percentage of the order size. It is not possible to use 
Percentage as the inspection type for parts that are used as a production 
schedule parts.
Prerequisites
  - The control plan template header 
	must be created.
- At least one Norm type must have been created. 
- At least one inspection code must have been defined. 
- For manufacturing control plan 
	templates, one or more work centers need to be defined. 
- For manufactured parts, it is 
	recommended that you also use routing templates to minimize the risk of 
	unwanted errors when applying the control plan template to control plans or 
	parts.
 
System Effects
As a result of this activity, one or more control plan 
template lines are created. The
inspection code selected in the control plan line, will control the sample size
for each data point when the analyses are created. The
inspection code selected in the control plan line will control the sample size
for each data point when the analyses are created.
Window
Control Plan Template
Related Window Descriptions
Norm Types
Inspection Codes
Work Center
 
Routing Template
Procedure
From the Control Plan  Template - Manufacturing
  - Create a new record.
- Note that the 
	Data Point field 
	is system-generated.
- Enter the 
Routing Operation No. 
This is a required field. 
- Enter the 
	Work Center No 
	or use the list of values to select a work center. 
- Enter a value for the Test Operation No. If you leave the field blank, the value is system-generated but it can be changed later. The first line created is number 10, the second is number 20, the
    third is number 30, and so on.
- Enter the 
	Test Operation Description. This is a required field.
- To make it mandatory to attach a media item to the 
	result, select the Media Required check box.
- Enter information in the 
	Evaluation Measurement Technique field, if
    appropriate.
- Enter information in the 
	Engineering Drawing Reference field, if
    appropriate.
- Enter the 
	Norm Type, or use the List of Values to choose from the
    available norm types. This is a required field.
- Enter information in the 
	Machine/Process/Tool, 
	Process Characteristic,
    Product Characteristic, and 
	Special Characteristic Classification fields, if
    appropriate.
- Select  Attributes, 
  Variables or Categorical in the 
	 
	Data Type list.
- If the data type is set to Categorical, enter a 
	Category ID or use the List of Values to choose from the available category 
	IDs.
- If the data type is set to Variable, enter information about the tolerance limits in the 
	Outer Min, 
	Inner Min,
    Nominal Value, 
	Inner Max and 
	Outer Max fields. The 
	nominal value is required, together with either the 
	combination Inner Min/Inner Max or Outer Min/Outer Max.
- Enter an Inspection Code or select one from the List of Values. 
- Enter information in the Sample Frequency and 
	Control Method
    fields. 
- Enter information in the 
	Reaction Plan and 
	Notes fields.
- Save when complete.
	
 
 Note: If the control plan template contains one 
or more control plan lines defined as Categorical, a Category Entry Type value 
must have been selected in the header section to be able to activate the 
template.
Control Plan Template -  Purchasing 
and Inventory
  - Create a new record.
- Note that the 
	Data Point field 
	is system-generated.
- Enter a value for the 
	Test Operation No. 
	If you leave the field blank, the value is system-generated but it can be 
	changed later. The first line created
    is number 10, the second is number 20, the
    third is number 30, and so on.
- Enter the 
	Test Operation Description. This is a required field.
- To make it mandatory to attach a media item to the 
	result, select the Media Required check box.
- Enter information in the 
	Evaluation Measurement Technique field, if
    appropriate.
- Enter information in the 
	Engineering Drawing Reference field, if
    appropriate.
- Enter the 
	Norm Type, or use the List of Values to choose from the
    available norm types. This is a required field.
- Enter information in the 
	Machine/Process/Tool, 
	Process Characteristic,
    Product Characteristic, and 
	Special Characteristic Classification fields, if
    appropriate.
- Select Attributes, Variables or Categorical in the 
	Data Type list.
- If the data type is set to Categorical, enter a 
	Category ID or use the List of Values to choose from the available category 
	IDs.
- If the data type is set to Variable, enter information about the tolerance limits in the
	Outer Min, 
	Inner Min,
    Nominal Value, 
	Inner Max, and 
	Outer Max fields. The 
	nominal value is required, together with either the 
	combination Inner Min/Inner Max or Outer Min/Outer Max.
- Enter an Inspection Code or select one from the List of Values. 
- Enter information in the Sample Frequency and 
	Control Method
    fields. 
- Enter information in the 
	Reaction Plan and 
	Notes fields.
- Save when complete.
Note: If the control plan template contains one or more 
control plan lines defined as Categorical, a Categorical Entry Type value must 
have been selected in the header section to be able to activate the control plan 
template.