Define Sample frequency trigger
Explanation
Use this activity to define which trigger types will be
used for a specific control plan 
template or control plan.
There are predefined trigger types in the  Trigger Type list.
The following trigger types are pre-defined for 
Control
Plan - Manufacturing:
  - Start Shop Order
- Nonconforming
- Time Interval
- Acceptance Sampling  
The following trigger types are pre-defined for 
Control
Plan - Purchasing:
  - At Arrival
- Time Scheduled
- Interval Scheduled
- Nonconforming 
- Acceptance Sampling  
Triggers can only be entered, modified, or deleted as
long as the control plan template or
control plan is in the Created status. 
  - The Start Shop Order, Nonconforming, and At
    Arrival trigger types can only be defined once for a specific 
	control plan template or control plan number. 
- The Time Interval,  Time Scheduled,
    and Interval Scheduled trigger types can be defined more than once for a specific
    control plan template or control plan number. However they have to be unique.
- Entering values in the Value
    and Unit of Measure  fields required if the trigger type is Time Interval
    or Time Scheduled.
- Entering a value in the Value field
    is required if the trigger type is Interval Scheduled. 
    
- The Acceptance Sampling trigger is 
	system-generated and connected to the data point when the acceptance sampling inspection code is used and 
	can only be used with that inspection code.
 
Prerequisites
The control plan template or control plan must be in the Created status.
System Effects
As a result of this activity, the defined triggers can
be connected to data points. Analyses will be created automatically, depending on the defined
sample frequency triggers.
  - Start Shop Order -This trigger creates an
    analysis when the status of the shop order is changed to Started.
- Nonconforming  - If an existing analysis is
    not fully expected, i.e., when the Variable Result Status  field has
    the Out of Specification or Partly Within Specification value, the Attribute
    Result Status field has the Nonconformities Exist value, 
	or the Category Result Status field has the 
	Nonconformities Exist value, this
    trigger will automatically create an analysis to assure 100% inspection.
- Time Interval - When the routing operation is started,
    this trigger type creates an analysis by the defined time interval, for
    example, every 10 minutes. For example, if you entered 1 in the Value field and Hours in the Unit
    of Measure field, the time interval between creating two analyses will be one
    hour.
 This will continue as long as the status of the routing operation number is
    Partially Reported. Analysis will only be created during working hours.
- At Arrival  - This trigger creates an
    analysis at every receipt, according to the data points defined for the
    trigger.
- Time scheduled - This trigger creates
    an analysis when the next receipt is made after the time interval is reached
    since the last analysis was created. For example, if you entered 2 in the Value field and
    Days in the  Unit
    of Measure field, an analysis will be created two days after the receipts are
    made.
- Interval Scheduled - This trigger
    creates an analysis when the value defined in the  Value field is
    equal to the
    number of receipts made. For example, if you entered 3 in the Value field, an analysis will be
    created after three receipts are made.
- Acceptance Sampling - With shop orders, 
	this trigger creates an analysis when the status of the shop order is 
	changed to Started. With purchase orders it creates an analysis at receipt. 
	The system will decide if it is necessary to create an analysis and 
	calculate the sample size according to the setup of Standard, 
	Inspection Level, Acceptance Quality Limit (AQL) and Sampling 
	Plan on the control plan.
 
Window
Control Plan Template
Control Plan -
Manufacturing
Control Plan -
Purchasing
Related Window Descriptions
Control Plan Template
Control Plan - Manufacturing
Control Plan - Purchasing
Define sample frequency
Procedure
  - Open the  Control Plan 
	- Manufacturing, Control Plan - Purchasing 
   
  or Control Plan 
  - Template
    window, and click the 
	Sample Frequency Trigger tab.
- Click the 
	Define  sub tab. 
    
- Create a new record by clicking New.
- Enter a description in the Trigger Description
    field. Entering a value in this field is required.
- Select a trigger type from the Trigger Type list. 
- If the trigger type is Time Interval, enter a number
    in the Value field and select a value from the Unit of Measure
    list. The possible values are Minutes, Hours, Days, and Months.
- Save the information. 
    
Note: The Acceptance Sampling trigger is defined 
and connected automatically when the acceptance sampling inspection code is 
used.